IMX RTC
Setting the RTC
If a wrong declation is present, hwclock command will fail.
First set the system date & time:
# date --set="20171231 23:59"
Then set the HW RTC using the system date & time:
# hwclock --systohc --utc
Power down your board, wait 5 minutes and power up again, then check you system date & time and verify it is correct:
# date
Wakeup using the RTC
All Variscite EVKs mount RTC ISL12057, however wakeup using the RTC requires hardware connection of ISL12057 IRQ2# pin to a SoC GPIO.
By default, the defconfig of latest kernels already enable the Intersil ISL12057 driver.
The kernel configuration item is available in Device Drivers -> Real Time Clock -> <*> Intersil ISL12057.
For DART-6UL on 6ULCustomBoard, RTC IRQ#2 pin is already connected to GPIO5_IO07, as declared in the file arch/arm/boot/dts/imx6ul-imx6ull-var-dart-6ulcustomboard.dtsi
rtc@0x68 { compatible = "dallas,ds1337"; reg = <0x68>; pinctrl-names = "default"; pinctrl-0 = <&pinctrl_rtc>; interrupt-parent = <&gpio5>; interrupts = <7 IRQ_TYPE_EDGE_FALLING>; };
For VAR-SOM-6UL on ConcertoBoard, you can short pins J14.8 & J14.10 and edit arch/arm/boot/dts/imx6ul-imx6ull-var-som-concerto-board.dtsi to declare GPIO1_IO10 as IRQ#2 pin.
rtc@0x68 { compatible = "dallas,ds1337"; reg = <0x68>; pinctrl-names = "default"; pinctrl-0 = <&pinctrl_rtc>; interrupt-parent = <&gpio1>; interrupts = <10 IRQ_TYPE_EDGE_FALLING>; };
For VAR-SOM-6UL on SymphonyBoard, RTC IRQ#2 pin is not connected: RTC has no wakeup capabilities.
Using rtcwake command
Assuming the your board has wakeup capabilities, to set the RTC to wakeup after 10 seconds type:
# echo enabled > /sys/class/rtc/rtc0/device/power/wakeup # rtcwake -m mem -d rtc0 -s 10
For more options, like waking up at a specific time, run:
# rtcwake --help